Reciprocating Maneurop Air Conditioning Compressor

Reciprocating Maneurop Air Conditioning Compressor

Danfoss Maneurop Reciprocating Compressors MTZ160HW4AVE 1.Product introduction: Maneurop Reciprocating Compressors Model NO: MTZ160HW4AVE Motor protection:Internal overload protector Type:MTZ Phase:3 Power Source: AC Power Transport Package: Wood Package Trademark:Maneurop(Danfoss) Origin:...

Description

Reciprocating Maneurop Air conditioning Compressor MTZ125HU4VE

 

Product introduction

Maneurop Reciprocating Compressors

Model NO: MTZ125HU4VE

Colour:Blue

Compressor power supply [V/Ph/Hz]:380-400/3/50 460/3/60

Power Source: AC Power

Connection type:Rotolock

Trademark: Maneurop(Danfoss)

Name Reciprocating Compressors
Model MTZ125HU4VE
Power 380-400V/50hz, 460V/60hz
Nominal cooling capacity at 50Hz 20KW
Technology Reciprocating
Color Blue
Min 1

To eliminate the problem of excessive exhaust temperature during compressor operation, you can do this:

Water-cooled condenser: The number of water pumps can be increased to increase the cooling water flow or the cooling tower fan speed to reduce the cooling water temperature; release the non-condensable gas mixed in the refrigeration system; remove the condenser pipe wall Scale.

Air-cooled condenser: Use a vacuum cleaner to absorb the dust in the fin gap; use a fin cleaner to clean the dirt on the fin; use a fin comb to repair the fallen fin.

 

Application for Maneurop compressors

1. Commercial refrigeration and refrigeration: Maneurop compressors are often used in refrigeration and refrigeration equipment in commercial places such as supermarkets, convenience stores and restaurants. They can be used in systems such as freezers, cold rooms and refrigerated trucks to provide consistent cooling capacity.

2. Industrial refrigeration: Maneurop compressors are suitable for various industrial refrigeration applications, such as cold storage, cooling towers, refrigeration equipment and refrigeration systems in industrial processes. They can meet different cooling requirements and provide high-efficiency cooling.

3. Air-conditioning system: Maneurop compressors are widely used in domestic and commercial air-conditioning systems. They are used in the refrigeration cycle between the condenser and the evaporator to achieve the air conditioning effect by cyclically compressing and releasing the refrigerant.

4. Heat pump system: Maneurop compressors can also be used in heat pump systems, including air source heat pumps, ground source heat pumps and water source heat pumps. Heat pump systems use a compressor to move heat from a low temperature area to a high temperature area for heating or cooling.

 

Reciprocating Maneurop Air Conditioning Compressor

Why is the oil temperature too high during compressor operation?

Usually, the oil level of the oil sight glass of the compressor is between the upper and lower limits of the oil sight glass and the lubricating oil is clean, not turbid, and the color is normal. Causes of excessive lubricating oil temperature during compressor operation:

① The suction and discharge temperature of the compressor is too high;

② The lubricating oil is too dirty or the oil quality is too bad;

③ The compressor parts are severely worn.

1

 

Maneurop compressor use and maintenance guide:

1. Installation: Before installing a Maneurop compressor, make sure to follow the installation guidelines and requirements. Make sure the compressor is properly connected to other system components and that the plumbing and electrical wiring are within code.

2. Operating parameters: When operating a Maneurop compressor, ensure that the operating parameters are within the range specified by the manufacturer. These parameters include pressure, temperature, and electrical requirements, among others. Operating parameters that are too high or too low may cause performance degradation or damage.

3. Maintenance Schedule: Establish a regular maintenance schedule that includes cleaning, lubricating, and inspecting the various components of the compressor. Clean the area outside and around the compressor to ensure good air circulation, and replace or clean the filter regularly.

4. Lubrication system: Maneurop compressors usually require lubricating oil to ensure proper operation and long life. Make sure to use the lubricating oil recommended by the manufacturer, and replace and replenish the lubricating oil according to the guidelines.

5. Regular inspection: Regularly check the operation status of the compressor, including pressure, temperature, noise and vibration, etc. Pay attention to any abnormal situation, and take appropriate measures such as cleaning, replacing parts or repairing in time.

6. Training and qualifications: Ensure that maintenance and operating personnel have the necessary training and qualifications. Understand the basic principles and operating requirements of compressors, and follow safe operating procedures.

In summary, proper use and maintenance of Maneurop compressors is essential to ensure their performance and longevity. Always follow the manufacturer's recommendations and guidelines, and seek professional help and support when needed.

 

FAQ

Q: What are the faults of the refrigeration compressor?

A: Refrigeration compressors may have various failures, such as compressor failure to start, condenser failure, evaporator failure, refrigerant leakage.

 

Q: What are the key points in the maintenance of refrigeration compressors?

A: The maintenance of refrigeration compressors requires attention to cleaning and regular replacement of filters, inspection and replacement of seals, regular inspection and calibration of controllers, inspection and replacement of condensers and evaporators, etc.

 

Q: How to solve the failure of the refrigeration compressor?

A: Solving the failure of the refrigeration compressor requires diagnosis and maintenance according to the specific situation. Common methods include replacing faulty parts, cleaning equipment, and calibrating the controller. If the fault is severe, it may be necessary to replace the entire compressor.

Hot Tags: reciprocating maneurop air conditioning compressor, manufacturers, suppliers, factory, cheap, in stock, Maneurop Compressor For Fruit Freezer, Maneurop Compressor For Vegetable Cold Storage, Maneurop Piston Compressor, 5HP Danfoss Refrigeration Compressor, Danfoss Piston Compressor For Refrigeration Unit, Maneurop Reciprocating Compressor