5HP Daikin Refrigeration Compressor
Here we guarantee on time delivery and if necessary, we will provide you the best logistics solution for the goods to reach at your location on time.
Description
5HP Daikin scroll Refrigeration compressor JT160GA-Y1 with R22
Product Parameter(specification):
|
Name |
Details |
|
Model |
JT160GA-Y1 |
|
Power |
380-415V/3 PHASE 50Hz |
|
Nominal capacity |
49800 |
|
Capacity |
79.2 |
|
COP |
3.4 |
|
Package |
pallet |
|
Application |
Air conditioning, HVAC system |
|
Origin: |
China |
Product detail
|
POWER |
MODEL |
PERFORMANCE |
CAPACITY |
|||||
|
SOURCE |
TESTING |
NOMINAL |
TNPUT |
CURRENT |
COP |
cm3/r |
||
|
POWER |
CAPACITY |
KW |
A |
W/W |
|
|||
|
SOURCE |
KW |
BTU/H |
|
|
|
|
||
|
380-415V/ |
JT125GABY1 |
380V/50Hz |
11.7 |
39900 |
3.44 |
6 |
3.4 |
63.2 |
|
3 PHASE |
JT125GA-Y1 |
380V/50Hz |
11.7 |
39900 |
3.44 |
6 |
3.4 |
63.2 |
|
50Hz |
JT160GA-Y1 |
380V/50Hz |
14.6 |
49800 |
4.3 |
7.5 |
3.4 |
79.2 |
|
JT160GABY1 |
||||||||
|
JT170GA-Y1 |
380V/50Hz |
15.6 |
53200 |
4.59 |
8.1 |
3.4 |
84 |
|
|
220V |
JT125GABTAL |
220V/60Hz |
13.9 |
47400 |
4.09 |
12 |
3.4 |
63.2 |
|
3 PHASE |
JT160GABTAL |
220V/60Hz |
17.4 |
59400 |
5.12 |
15.2 |
3.4 |
79.2 |
|
50/60Hz |
JT170GABTAL |
220V/60Hz |
18.6 |
63500 |
5.47 |
16.1 |
3.4 |
84 |
Product qualification
Certificate, certification, patent certificate:
(1)."Quality Management System Certification"
(2)."Shenzhen Science and Technology Enterprise Certification"
(3)."Refrigeration Equipment Air Conditioning Maintenance and Installation Enterprise Qualification Certificate"

What is the function of a scroll compressor?
A scroll compressor, alternatively known as a spiral compressor, scroll pump, or scroll vacuum pump, is designed for the compression of air or refrigerant. This versatile device finds applications in air conditioning systems, automobile superchargers (referred to as scroll-type superchargers), and as a reliable vacuum pump.
FAQ
(1).What is your delievery time?
1).The time of delievery is 3-10 working days after payment.
(2).Why does the compressor vibrate for a short time after starting?
1).Inhaling excessive lubricating oil or liquid
2).The compressor accumulates oil and liquid strike occurs
Hot Tags: 5hp daikin refrigeration compressor, manufacturers, suppliers, factory, cheap, in stock, Daikin Scroll Refrigeration Compressor, R22 Daikin Scroll Air Conditioning Compressor, 5HP Daikin Refrigeration Compressor, Daikin Hermetic Scroll Compressor, Daikin Scroll Compressor, Daikin Scroll Compressor For Inverter Conditioning