Copeland Semi-closed 10 HP Compressor D3SC-100X-AWM

Copeland Semi-closed 10 HP Compressor D3SC-100X-AWM

1.Product introduction DWN Series Copeland Semi-hermetic Compressor Model NO.: D3SC-100X-AWM 10HP Cooling System: Air Cooling Cylinder Position: Vertical Compress Level: Single-Stage Performance: Low Noise Drive Mode: Electromagnetic Power Source: AC Power Cylinders: 3 Transport Package: Wooden...

Description

Copeland Semi-closed 10 HP Compressor D3SC-100X-AWM

 

Product introduction

DWN Series Copeland Semi-hermetic Compressor

Model NO.: D3SC-100X 10HP

Cooling System: Air Cooling

Cylinder Position: Vertical

Compress Level: Single-Stage

Performance: Low Noise

Drive Mode: Electromagnetic

Power Source: AC Power

Cylinders: 3

Transport Package: Wooden package

Origin: Belgium

Lubrication Style: Lubricated

Cylinder Arrangement: Balanced Opposed Arrangement

Refrigerant Type: Freon

Piston Type: Closed

Trademark: Emerson Copeland

Package: 1pc/Wooden package

Certification: CE

Application: Air conditioning, HVAC system

 

Production details

Copeland Semi-closed 10 HP Compressor D3SC-100X

Technical data:

Nominal motor power [HP]: 7.5

Displacement [m³/h]: 32.33

Weight [kg]: 175

Oil charge [dm³]: 3.5

Voltage: 380-420V/3/50Hz

Displacement: 32.3cc/rev

Capacity: 3800kBtu/h

COP: 3.55W/W

Electrical data :

Power supply [V/~/Hz]: 380-420V/3/50Hz

Locked rotor current [A]: 78.5

Max. operating current [A]: 11.2

Winding resistance [Ω]: 1.35

Connections:

Suction line: 7/8"

Discharge line: 6/7"

 

Semi-enclosed piston machine can not establish oil pressure how to deal with?

1. Check the oil pump piping system connection has no oil leakage or blockage is leakage. If the connection is loose, the joint should be tightened; if it is blocked, the oil pipeline should be unblocked.

2. Is the oil pressure regulating valve open too large or with the spool off. If the oil pressure regulating valve is not properly adjusted, the oil pressure regulating valve should be adjusted and the oil pressure should be adjusted to the required value; if it belongs to the valve spool off, the valve spool should be reinstalled and fastened firmly.

3. If the oil in the crankcase is too little or the presence of refrigerant, it will lead to the oil pump does not feed oil. If the oil is too little should be timely refueling; if the latter, to stop in time to exclude the refrigerant.

 

FAQ

Q: What is your order quantity?

A: Our starting order quantity is usually 1 piece.

 

Q: How long does it take for deliveries?

A: After payment, the delivery window is 3–10 working days.

 

Hot Tags: Copeland Semi-closed 10 HP Compressor D3SC-100X-AWM, manufacturers, suppliers, factory, cheap, in stock, Compressor For CPL, DWM Compressor For Cold Storage Unit, 50HP DWM Semi hermetic Compressor, Semi hermetic Compressor For Sanyo, CPL 7 5HP Semi hermetic Compressor, 15HP CPL Compressor For Cold Room