Semi-hermetic Compressor For Bitzer Cold Room
video
Semi-hermetic Compressor For Bitzer Cold Room

Semi-hermetic Compressor For Bitzer Cold Room

Model:2EES-2Y

MOQ:1pcs

Suction gas temperature:20℃

origin of place:China

Power voltage:400V-Y(40s)

Freq:50Hz

Enclosure class:IP66

Description

High Performance Semi-hermetic Compressor for Bitzer Cold Room 2EES-2Y


Air Therapy:


We depend more and more on our air handling systems to provide a comfortable interior environment as we spend more and more time indoors. Modern air handling units maximize air flow, maintain a pleasant indoor temperature, and consume the least amount of energy possible. They may also include active and/or passive heat recovery. By lowering the quantity of common pollutants like dust, mold, pollen, smoke, radon gas, etc., it also contributes to a considerable improvement in air quality. Learn about BITZER's offerings in this area.


Details:

Model:2EES-2YFreq (Hz) :50
Max. pressure (LP/HP) :19 / 32barorigin of place :China

Displacement

(1450 RPM 50Hz) :

11,36 m3/hCertification :CE
Oil type R134a :BSE32(Standard) | R134a tc>70°C: BSE55 (Option)Warranty :1 Year
Power input (kW) :3,3Application :Refrigeration Parts
MOQ :1pcsType:Refrigeration Compressor
Starting current (A) :26.0Net Weight (kg) :74

bitzer


Products information :


Semi-hermetic Compressor for Bitzer Cold Room 2EES-2Y

Brand: Bitzer

Model: 2EES-2Y

Refrigerant: R134a

Oil charge: 1,00 dm³

MOQ: 1 piece

Voltage: 380-420V Y-3-50Hz

Application: HVAC

No. of cylinder x bore x stroke: 2 x 46 mm x 39.3 mm


bitzer condensing unit


How to prevent oil pipe blockage in BITZER compressors?


Generally speaking, mud and sand, welding slag, cotton yarn head and other debris may block the oil pipe, so that the lubrication point less oil or no oil, resulting in overheating and wear, or make the oil supply plunger outlet resistance is too large and cause damage. When the oil pipe is blocked, the oil supply point has no oil, the blocked section of the pipe is likely to occur in front of the oil leakage or occurrence of the oil injection point of the oil supply plunger damage and other phenomena. To prevent blockage of the lubricating oil pipe, the following measures should be taken.

(1) Before installation, the oil pipe should be cleaned one by one, preferably by alkaline washing, water washing and white cloth rubbing or by blowing clean with air with pressure.

(2) When the oil pipe is not long enough and needs to be lengthened, a live joint should be fitted or a casing should be used to weld the lengthening to avoid blocking the pipe with welding slag or molten metal.

(3) bend the tube with a simmering tool cold bending or oxygen b fast flame heating simmering, should pay attention to prevent simmering flat or metal overheating and deformation.

(4) oil pipe and oil injector assembly, the strength of the system should be tested, the test pressure for the operating pressure of 1.5 times, when found to have leakage or rupture, should be repaired or replaced.

(5) oil injector and stuffing box, cylinder oil supply point connected before, should be the first oil machine open up, in each oil supply point to check the oil situation and cleanliness, until clean, and then officially connected to the joint.


Hot Tags: semi-hermetic compressor for bitzer cold room, manufacturers, suppliers, factory, cheap, in stock, 25HP Bitzer Semi Hermetic Compressor, 20HP Bitzer Semi hermetic Compressor, 40HP Bitzer Semi hermetic Compressor, 4HP Bitzer Compressor, 15HP Bitzer Refrigeration Compressor, Semi hermetic Compressor