380V/3pH/50Hz R404A Compressor Copeland Zb15kq-Tfd-558 Zb15kqe-Pfj-524
Separate and clean each pipeline in the system, pour the pipeline condenser with cleaning, soak in the evaporator for about 20 minutes, and then use high-pressure oxygen to remove the cleaning and dirt.
Description
'Honesty as base, Sincere assistance and mutual profit' is our idea, in an effort to create consistently and pursue the excellence for GMCC R22 Rotary Compressor, Danfoss Scroll Compressors, Daikin Scroll Compressor. Our objective is to ensure that our company adapts to the changing market environment in an overall and planned way, and to seek the survival and growth. For further information, please don't hesitate to contact with us. Equality, mutual benefit, and common development are our cooperation philosophy with friends from all over the world. We can easily offer you by far the most aggressive prices and good quality, because we've been much additional Specialist!
Good Price Scroll Compressor Of ZSI15KQE-TFP-537
Product introduction
ZSI Series Copeland Scroll Compressor
|
name |
Scroll compressor |
|
Model |
ZSI15KQE-TFP-537 |
|
Power |
380V/3/50Hz |
|
Displacement |
14.4 m³/hr |
|
Oil Charge |
1.36 L |
|
Horse Power |
5HP |
|
Package |
16pcs/pallet |
|
Application |
Air conditioning, HVAC system |
Product feature and application
Refrigerant Freq (Hz) Phase Voltage Application
R-22 HFC 50 3 380V Low Temperature
R-404A HFC 50 3 380V Low Temperature
Installation Instructions:
1). Separate and clean each pipeline in the system, pour the pipeline condenser with cleaning, soak in the evaporator for about 20 minutes, and then use high-pressure oxygen to remove the cleaning and dirt.
Flush out together, do not clean the compressor dryer bottle, accumulator, and tube. and ensure that no cleaning fluid remains in the system,
If necessary, use nitrogen to dry the refrigerant circuit.
2). Clean the surface of the condenser and evaporator, and check whether the speed of the radiator fan is normal.
3). Expansion valve cleaning or replacement of the filter capillary must be replaced, insufficient capacitance needs to be replaced.
4). Before installation, the compressor can be energized to test that the compressor is normally welded, evacuated, and nitrogen filled to check the high and low pressure. If the pressure is
abnormal, please diagnose the cause and install it.
5). Refilling genuine snow, fake and inferior snow will affect compressor used.

We are committed to making every 380V/3pH/50Hz R404A Compressor Copeland Zb15kq-Tfd-558 Zb15kqe-Pfj-524 a high-quality product, so that we attach great importance to technological progress and development. We carry forward the spirit of unity, pragmatism, development and progress and strive to create a corporate image of integrity, vitality and efficiency. In the future, we will make continuous improvement in product R & D, market development and service level, strive to become a trusted and good brand supplier for customers, and provide them with comprehensive professional solutions.
Hot Tags: r404a copeland compressor, manufacturers, suppliers, factory, cheap, in stock, Compressor For Copeland, Performer Scroll Compressor For Fruit Freezer, R22 Daikin Scroll Air Conditioning Compressor, 50HP Refcomp Screw Compressor, SECOP Commercial Compressor, New Copeland Commercial Compressor