Dixell Egg Incubator Temperature Controller Stc-1000

Dixell Egg Incubator Temperature Controller Stc-1000

Another parameter "Fs" can set a temperature. When the temperature of the detector of the evaporator exceeds this temperature, the fan always stops.

Description

Our technical talent team provides a strong guarantee for the continuous optimization of product quality, and also lays a solid foundation for our first-class 380V Danfoss Hermetic Compressor, KP1 Pressure Switch For Danfoss, Tecumseh Compressor For Refrigeration Unit. We sincerely welcome you to make progress hand in hand with us, and construct a prosperous future together. We sincerely hope we can establish win-win business cooperation with you in the future! Our company adheres to the corporate spirit of 'loyalty, benevolence, diligence, and innovation', has gathered a large number of outstanding talents and established a strong core leadership team. And then E-mail us your specs or inquiries today.

Good Price DIXELL Controllers XR Series XR06CX-5N0C1

 

Product introduction

Model: Xr06cx-5N0C1

1).External dimension 32 x 74 x 60 mm is a micro temperature controller suitable for medium / low temperature forced air cooling refrigeration system, with three outputs: one compressor, one evaporator fan and one defrosting (electric heating or hot gas), two NTC probe inputs: one is the storage temperature and the other is the evaporator temperature(Defrost termination temperature + fan stop temperature control), a passive digital switch input; parameters can be set or programmed by keyboard on the panel (hot key).

 

2).The state of the compressor output is based on the temperature measured by the probe. When the temperature is greater than or equal to the set value + hy, the compressor output contact is closed and the compressor runs; when the temperature is less than or equal to the set value, the compressor output contact is open and the compressor stops running.

 

Defrosting

Parameter "TD" gives the defrost type:

Td = El → electric defrosting (when defrosting, the compressor output relay is disconnected)

Td = in → hot gas defrosting (compressor output relay is closed during defrosting)

Other parameters include: parameter "Id" gives defrosting time interval, i.e. how long is defrosting once, while defrosting duration is maximum

The time is given by the parameter "MD"; the parameter "de" gives the defrost termination temperature; it should be noted that no matter "MD"

"De" will exit from defrosting when any condition arrives, while "de" exit and "MD" are generally used to prevent excessive defrosting protection

A dripping time can be set after defrosting, which is set by the parameter "DT". When DT = 0, it means none.

 

Fan

Parameter FC has the following options to determine the operating mode of the fan:

FC = cn → fan and compressor start and stop at the same time, and stop when defrosting

FC = on → the fan operates all the time except when it stops during defrosting.

 

After defrosting, you can set a delay time of fan start corresponding to the dripping time through the parameter "FD".

 

FC = CY → fan and compressor start and stop at the same time, and operate during defrosting

FC = oy → continuous operation of fan (including defrosting period)

 

Another parameter "Fs" can set a temperature. When the temperature of the detector of the evaporator exceeds this temperature, the fan always stops. Only when the temperature is lower than this temperature, the fan can operate, and the air flow can flow, so as to ensure that when the temperature of the evaporator is higher, the heat will not be brought to the space in the warehouse.

 

Shipping, Payment and Delivery

1).Shipping:

1. For Sample order in stock, we aim to ship the compressor within 3 days.

2. For any Bulk order, generally we ship compressor in 10-15 working days after receiving deposit.

 

2).Payment:

1. T/T

2. Western Union

 

3).Delivery:

Here we guarantee on time delivery and if necessary, we will provide you the best logistics solution for the goods to reach at your location on time.

 

FAQ

1). What is your MOQ?

---Our MOQ is usually 1 set.

 

2). What is the price?

---The price is depends on the quantity

 

3). What is your delievery time?

---The time of delievery is 3-10 working days after payment.

 

XR06CX 5NOC1 Dixell controller  (4)

New Delivery for Dixell Egg Incubator Temperature Controller Stc-1000. Our company always adheres to the business philosophy of 'science and technology as the guide, marketing as the leader, quality as the center'. In order to enable customers to get the most efficient service in the shortest time, we constantly develop and introduce the latest specifications of products to expand and enrich the inventory to meet the customer's requirements.

Hot Tags: dixell controller for compressor, manufacturers, suppliers, factory, cheap, in stock, Hermetic Piston Compressor For Maneurop, Danfoss TS2 Expansion Valve, Mitsubishi Air Conditioning Compressor, Dandfoss Hermetic Filter Drier, 240HP Bitzer Compressor For Cold Storage, 8HP Refrigeration Compressor

[[ProKeywords]]