R404A, 10HP, 50Hz, 3-Phase, 380V Copeland Compressor Zb76kqe-Tfd-551
Separate and clean each pipeline in the system, pour the pipeline condenser with cleaning, soak in the evaporator for about 20 minutes, and then use high-pressure oxygen to remove the cleaning and dirt.
Description
Our diversified 380V Sanyo Semi-hermetic Compressor, Semi-hermetic Compressor For Sanyo, Rotary Compressor For GMCC and services, strong market penetration and influence have played a positive role in our economic development. Our high-quality service runs through the entire product cycle, with technology as the forerunner and service as the backing to ensure customer satisfaction and develop together with customers. Welcome new and old friends from all walks of life to our company to visit, inspect and call us to discuss cooperation matters. After years of development and under the support of our customers, our products have been greatly improved from quality to quantity. We vigorously promote scientific and technological innovation and management innovation, constantly enhance our market competitiveness and improve business efficiency. We firmly believe that marketing is the source and R&D is the backing.
Good Price Scroll Compressor Of ZSI15KQE-TFP-537
Product introduction
ZSI Series Copeland Scroll Compressor
|
name |
Scroll compressor |
|
Model |
ZSI15KQE-TFP-537 |
|
Power |
380V/3/50Hz |
|
Displacement |
14.4 m³/hr |
|
Oil Charge |
1.36 L |
|
Horse Power |
5HP |
|
Package |
16pcs/pallet |
|
Application |
Air conditioning, HVAC system |
Product feature and application
Refrigerant Freq (Hz) Phase Voltage Application
R-22 HFC 50 3 380V Low Temperature
R-404A HFC 50 3 380V Low Temperature
Installation Instructions:
1). Separate and clean each pipeline in the system, pour the pipeline condenser with cleaning, soak in the evaporator for about 20 minutes, and then use high-pressure oxygen to remove the cleaning and dirt.
Flush out together, do not clean the compressor dryer bottle, accumulator, and tube. and ensure that no cleaning fluid remains in the system,
If necessary, use nitrogen to dry the refrigerant circuit.
2). Clean the surface of the condenser and evaporator, and check whether the speed of the radiator fan is normal.
3). Expansion valve cleaning or replacement of the filter capillary must be replaced, insufficient capacitance needs to be replaced.
4). Before installation, the compressor can be energized to test that the compressor is normally welded, evacuated, and nitrogen filled to check the high and low pressure. If the pressure is
abnormal, please diagnose the cause and install it.
5). Refilling genuine snow, fake and inferior snow will affect compressor used.

We focus on the development and design of R404A, 10HP, 50Hz, 3-Phase, 380V Copeland Compressor Zb76kqe-Tfd-551 solutions. Our company will adhere to 'Quality first, , perfection forever, people-oriented, technology innovation' business philosophy. Our company has become an excellent supplier of major system projects with our thoughtful and rigorous service attitude.
Hot Tags: r404a copeland compressor, manufacturers, suppliers, factory, cheap, in stock, R22 Sanyo Hermetic Compressor, Low Temperature Scroll Compressor Of Copeland, 380V Copeland Scroll Compressor, R410a Mitsubishi Invert Compressor, Emerson Refrigeration Air Conditioning Compressor, R22 Hitachi Scroll Compressor
[[ProKeywords]]Send Inquiry
You Might Also Like
-

Danfoss Closed Type Scroll Compressor
-

15HP Copeland Air Conditioner Compressor Vr190ks-Tfp...
-

Tecumseh Refrigeration Compressor Model Caj4517e
-

380V 50HP Dwm Copeland Semi-Hermetic Compressor D8dh...
-

SANYO Refrigerated Compressor Condensing Unit Pad fo...
-

Performer Scroll Compressor (SZ/SY/SM, R134A/R407C/R...